Damocles 1208 - 12 potentialfreie Kontakte, 8 Relais Ausgänge, WEB-Server, E-Mail, SNMP Traps, M2M Protokol (SNMP, XML, Modbus/TCP)

Damocles 1208

 
Damocles 1208
• Preisliste zusenden • Anfrage
 

Damocles 1208 is a device with 12 remote inputs and 8 outputs over Ethernet with Web interface. M2M communication for connection to SNMP and SCADA systems. Pulse counters on digital inputs. E-mail and SNMP trap notifications of input state changes. Box-2-Box mode - outputs can be controlled over the LAN by another device.

Damocles 1208 provides digital inputs (DI) and digital outputs (DO) that can be remotely controlled over the Web.
Inputs and outputs can also be controlled over the network using M2M protocols (SNMP, Modbus/TCP, XML over HTTP).

When an input dry contact state is changed (closed/open), Damocles sends an e-mail with customizable text and/or a SNMP Trap.

* Pulse counter on every input (32 bits)
* Box-2-Box mode: Outputs can be controlled over the IP network using sensors of another device
* M2M protocols: SNMP, Modbus/TCP, XML (over HTTP)

Typical application of Damocles 1208 involves energy consumption monitoring by counting pulses from meters. The HWg-PDMS application converts pulses to kWh per time period and creates MS Excel output reports.

Features:

# Ethernet: RJ45 (10BASE-T)
# WEB: Built-in web server
# Inputs: 12 digital inputs (for dry contacts)
# Outputs: 8 digital outputs (open collector, max. 24V)
# Box-2-Box mode: Outputs are activated by alerts from other devices (Poseidon / Damocles)
# M2M communication protocols: SNMP, XML, Modbus/TCP

# Reaction to changes at the input: SNMP trap, Email (editable text)
# Mechanical: 140 x 90 x 40 [mm], wall-mountable, fits on a DIN rail

# Support for programmers: HWg SDK
# I/O over EthernetSupported software

* HWg-PD Trigger: Controls other IP devices, redirects alarms to SMS
* HWg-PDMS: Logging, conversion of pulses to energy, export to MS Excel, reports
* CapTemp: Visualization on a map, control of outputs, alarm redirection to SMS
* >> Third-party SNMP software
(Nagios, The Dude, Zabbix, IBM Tivoli, HP OpenView, OpManager, IMM (Intellipool Network Monitor), Monitor one, Cacti, MRTG, Opsview, LoriotPro, Axence nvision, Ipswitch WhatsUp, Paessler IPCheck, MSC Operations Manager 2007)

 
Damocles 1208
 

BOX-2-BOX:

Box-2-Box mode lets you use a Damocles unit as remote outputs. Outputs of the Damocles unit signal the OK or Alarm states of sensors and inputs at other devices. Any Poseidon, Damocles or HWg-WLD device can activate the outputs of a Damocles 1208 unit over the network. This feature does not require any software.

* High temperature at the air conditioning outlet (Poseidon 3262) turns on a warning light in the IT department in another building (Damocles digital output).
* 7 water leak detectors laid out in one floor of an office building control outputs O1 through O7 over IP. All outputs control a warning light and a horn. In case of flooding, the horn sounds, and the indication of output states on the Damocles 1208 unit informs the operator about the exact zone.

 
Damocles 1208
 

Usage examples

web I/O, modbus tcp I/O, DO control remote, pushbutton e-mail, IP pulse counter, s0 eletricity meter, energy consumption metering

* Remote equipment monitoring
Monitoring of A/C, UPS, security system status (status relays)

* Energy consumption monitoring
Counting of pulses from electricity / water / gas meters. Conversion to price using HWg-PDMS in MS Excel.

* Alarm alerts
Turning on a warning light or a horn upon alarm at another unit (over the network, Box-2-Box mode)

* UPS and back-up generator monitoring: Fuel level, diesel generator status, remote start over IP

* Security systems
o IP surveillance systems (external sensors)
o Equipment status, access control systems
* SCADA: Connection of external inputs to multiple independent systems

 
StartseiteKontaktAGBSchutzrechtshinweis und HaftungsausschlussImpressum