Poseidon 2250 SNMP Ethernet Environmental Monitoring und Data Logger über SNMP, E-Mail und SMS

Poseidon 2250

 

Poseidon 2250
• Preisliste zusenden • Anfrage
 

Poseidon 2250: SNMP monitoring & data logger

Poseidon 2250 logs the values from up to 40 probes (RS-485, dry contacts, temperature, voltage, and more). Data are stored in a flash memory. The device enables monitoring over IP (Web, SNMP, Modbus/TCP) and sends alerts to values out of range (e-mail, SNMP trap, SMS over GSM). Industrial probes (4–20mA and Pt100/Pt1000) are supported. The supplied HWg-PDMS application enables native export of data to MS Excel.

Poseidon 2250 monitors the values of external probes and dry contact inputs, and stores the values in its internal memory. Up to 40 probes can be connected, maximum distance is 1000 m.
Poseidon 2250 supports low-cost probes for IT environment, as well as precise platinum temperature probes (Pt100, Pt1000) and industrial probes (4–20 mA / 0–10V interface) connected over RS-485.

Values captured from all probes (max. 40) are periodically stored into the internal flash memory. Stored values can be periodically e-mailed, imported into a database, or processed in MS Excel (thanks to native MS Excel export using the HWg-PDMS utility).

Typical applications include measuring and logging temperatures in a pharmacy. Poseidon 2250 measures the temperature in four refrigerators, and monitors their doors. Values are stored in the internal memory and periodically e-mailed to a central server for processing.

* Values are logged to the flash memory. Nothing is lost even in case of power failures.
* All sensors sold by HW group are supported (both 1-Wire UNI and RS-485).
* Supports a GSM modem to send SMS alerts.

Features:

# Ethernet: RJ45 (10BASE-T)
# Logging of values: Internal flash memory, 384 KB
# WEB: Embedded WEB server / GUI
# 1-Wire UNI probes: 1xRJ11 (max 10 probes)
Temperature, humidity, voltage, AC current, airflow, water leak, and more...
# RS-485 sensors : 1xRJ45 (max 26 probes)
(Temperature, humidity, pressure, voltage, current, lighting, ...)
# Digital Inputs: 3 dry contact inputs (for detectors)
(Smoke, 110/230V power, water leak, door contact, air flow, entry to the room)
# Digital Outputs: 2 digital outputs (RS-232 outputs)
# GSM modem: A GSM modem for sending text messages (SMS) can be connected to RS-232
# Mechanical: Wall mount, dimensions: 25 x 82 x 90 [mm]
# Warranty: 5 years
# Alerts (value out of defined safe range): SNMP trap alert, e-mail alert, web sms alert (SMS via GSM modem)
# M2M communication protocols: SNMP, XML, Modbus/TCP

# Support for programmers: HWg SDK

# Supported software

* HWg-PDMS: Logging, export to MS Excel
* CapTemp: Visualization on a map, control of outputs, alarm redirection to SMS
* HWg-PD Trigger: Controls other IP devices, redirects alarms to SMS
* >> Third-party SNMP software
(Nagios, The Dude, Zabbix, IBM Tivoli, HP OpenView, OpManager, IMM (Intellipool Network Monitor), Monitor one, Cacti, MRTG, Opsview, LoriotPro, Axence nvision, Ipswitch WhatsUp, Paessler IPCheck, MSC Operations Manager 2007)

Usage examples

* Pharmacies: Monitoring and logging of storage conditions for pharmaceuticals
* Bakeries, freezing plants: Monitoring of temperatures in the industry processes, HACCP reporting
* A/C monitoring (HVAC): Long-term monitoring of system parameters, temperature humidity logger
* Storages: Monitoring of temperatures, humidities, and other conditions; HACCP-compliant monitoring
* SCADA systems: Connecting inputs of external values

 
Poseidon 2250
 

Probes

Probes: humidity, temperature, AC voltage, 4-20mA,0-10V, DC voltage, water leak, air-flow, etc.Each probe has an individually-configurable name and safe range. When the safe range is exceeded (alarm), e-mail, SMS or SNMP trap is invoked.

RS-485 probes

* Total bus length up to 1000 m
* Temperature - Temp-485 / Spider
* Pt100 / Pt1000 temperature - Temp-485-Pt100
* Humidity - HTemp-485 / HTemp-485 Txxxx / Spider

* Air pressure - HTemp-485 Txxxx
* Voltage (0–10V) / current (0–20mA) sensor - Sens-UI 485
* Hub: S-Hub

1-Wire UNI probes

* Total bus length up to 30 m
* Temperature - Temp-1Wire

* Humidity - Humid-1Wire
* Air flow
* Voltage - 0..15V DC - Sensor 15V 1W-UNI
* DC voltage 0–60V - Sensor 60V 1W-UNI
* Current - 0-20mA DC - Sensor 20mA 1W-UNI
* AC current 0-30A - 30A Current probe 1W-UNI
* Light sensor
* Combined sensor Sens-1W-UDI86: 8 voltage inputs (0-15 VDC), 6 dry contact inputs
* Hub: T-Box

Dry contact inputs (for detectors):

* Water flood detector: Flood detector
* Gas leak detector: Gas leak detector
* Smoke detector: Smoke detector
* Motion detector: Motion detector
* Open/closed door detector: Door contact

Digital outputs (relays)

* To connect an external relay: P1250 RC (Relay Cable), DIN relay
* Electricity supply control: PowerEgg to detect and control 110/230V

 
StartseiteKontaktAGBSchutzrechtshinweis und HaftungsausschlussImpressum